19W LED Microwave Switch Occupancy Sensor

Sales 19W LED Microwave Switch Occupancy Sensor

HT19V 2 is a LED Driver&Microwave Sensor 2-in-1 Products with 30-54V Output Voltage Detection Range & Height of 6m(H) x 14m(D), Dimming Function Microwave Motion Detector with 12-19W Output Power Suitable for Ceiling Light
  • Certification : CE,ROHS,TUV,RED

Product Detail  

19W LED Driver & Microwave Sensor Constant Current 0.3A/0.35A Ceiling Light 14M(D)x6M(H)

HT19V 2 is a LED Driver&Microwave Sensor 2-in-1 Products with 30-54V Output Voltage Detection Range & Height of 6m(H) x 14m(D), Dimming Function Microwave Motion Detector with 12-19W Output Power Suitable for Ceiling Light

Features:

1. 3 years warranty, IP20

2. Abnormal protection SCP: Auto recovery, OVP, OCP, OTP

3. Tri-level control by 1-10V output

4. Dusk & Dawn Microwave Motion Sensor

5. Dimming Function with 10%/20%/30%/50% Stand-by Brightness

6. Constant Current with options of 0.3A/0.35A

7. Detection Range x Height of 14M x 6M

8. Output Power 19W max. with Voltage of 30-54V

9. Efficiency of 87%

10. Empty Load voltage of 63V max.

11. EMC standardEN55015

Product Description

Input voltage 220~240VAC 50/60Hz
Input current 0.1 Max
Input power 22W Max
Detection area 50%/100%
Hold time 5s/60s/ 5min/10min
Daylight threshold 2Lux /10Lux /50Lux/Disable
Stand-by period 0s/10s/10min /+∞
Stand-by dimming level 10%/30%
Microwave frequency 5.8GHz±75MHz
Microwave power <0.3mW
Detection angle 30°-150°
Mounting height Max.6m
Detection range Max.ø14m
Output LED current 0.3A/0.35A±5%
Output LED voltage 30-54V
Output LED power 12-19W Max.
Empty load voltage ≤63V
Power factor >0.9
Efficiency 87% (Max.)
Operating temperature Ta: -20°C+50°C Tc: 80°C
Abnormal protection SCP:Auto recovery,OVP,OCP,OTP
EMC standard EN55015
Safety standard EN61347-1 EN61347-2-13 EN60598-1
IP rating IP20
Life time 30,000 hours
Warranty 3 years

Detection Range

This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.

Typical installation height 2.5-6m.

Mechanical structure

With eight DIP switch poles to set all parameters

With two DIP switch poles to choose different output current

With two installation hole, easily fixed to the lighting fixture for end user.

Wiring diagram

Two poles to connect with power supply (220-240VAC)

Two poles to connect with LED Light

Dimensions (mm)

DIP Switch Setting

Detection area Hold-time Daylight threshold Stand-by period Stand-by dimming level

In this area, The period of Definition of the The period of light The definition of movement will light keeping ambient brightness; keeping low output low output in the be detected 100% brightness only when the before it's standby period.
and able to after moving ambient brightness completely trigger the objects leave the is lower than the switched off. When sensor. 100% detection area. preset specific lux it's preset as"∞“,detection area amount, the sensor the light always is also known will work; when it's keep at low output as the strong preset as "disable", if no movement in sensitvity. the sensor works the detection area 
everytime it detects and doesn't turn off.

motion regardless the ambient brightness.

Output Current Setting

Set the current to be 350mA by plugging black cap on 1&2 PIN, and 300mA by plugging on 2&3 PIN.

Daylight Priority

With Daylight priority function, HT19V-I is able to differentiate artificial light brightness
from natural light after installed inside the fixture, and automatically turn off light when
ambient brightness exceeds preset lux level.

Precondition of Daylight priority:
1. Standby period is +∞;
2. Standby dimming level is on 10% or 30%;
3. Daylight threshold is on 2Lux, 10Lux or 50Lux.

Application Demo

1. Automatically ON/OFF function:

Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
The daylight threshold is set to "2lux,10lux,50lux"

With sufficient daylight, With insufficient daylight, After the last detection and
even when motion detected, when motion detected, light ON. the present hold time
light remains OFF. elapsed, light OFF.

2. No daylight function
The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off after stand-by period.
Applications: Dim places such as Basement Parking, Underpass.

When motion is detected, After people leave the detection After the last detection and
the sensor will switch on the area, light remains 100% the present hold time
light to 100% brighteness. brightness within hold time. elapsed, light OFF.

3. Function Demo - Dimmable control/Corridor function

With sufficient daylight, With insufficient After last detection, After the stand-by
even when motion daylight, when motion light will be dimmed period, light OFF.
detected, light remains detected, light ON. down to the stand-by
OFF. dimming level (10% or

30%) after holdtime.

Installation Method:

User Notes:

1. Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.

2. Detection area will be affected by speed of motion, mounting height and movement volume.

3. Conduct test on sunny days without the lampshade which will affect the tested lux value.