Cotran heat shrink terminations (indoor/outdoor) are precisely designed to meet the parameters of international cable and cable accessories standards such as CENELEC HD 629.1 S1, IEEE-48, IEEE-404, IEC60502. Our heat shrink terminations offers reliable and consistent performance for longer service life. We have designed our heat shrink terminations for single core and 3 cores extruded UA, SWA/STA, CWS/CTW cable through 36KV.
Main Kit Components
Insulation tube |
Anti-track tube |
Stress control tube |
Breakout Slective |
Tube for outer sheath |
Rain shed skirt |
Sealants |
Coding tube |
Braid |
Silicone grease |
Spring roll |
Instruction |
Selective Chart
Part NO. |
Cable cross-section (mm2) |
O/D of main insulation (mm) |
Voltage |
CHST-XT-15-Y/1 |
25~50 |
12.3~20.7 |
8.7/15kV |
CHST-XT-15-Y/2 |
70~120 |
20.7~26.9 |
8.7/15kV |
CHST-XT-15-Y/3 |
150~240 |
26.5~32.7 |
8.7/15kV |
CHST-XT-15-Y/4 |
300~400 |
31.9~40.9 |
8.7/15kV |
CHST-XT-24-Y/1 |
35~95 |
18.0~22.5 |
12/20kV |
CHST-XT-24-Y/2 |
120~240 |
23.9~29.3 |
12/20kV |
CHST-XT-24-Y/3 |
300~400 |
31.5~34.5 |
12/20kV |
CHST-XT-36-Y/1 |
50~95 |
24.3~27.3 |
18/30kV |
CHST-XT-36-Y/2 |
120~185 |
28.9~32 |
18/30kV |
CHST-XT-36-Y/3 |
240~400 |
34.3~39.5 |
18/30kV |
Notes: X indicates indoor or outdoor termination, eg. IT indicates indoor termination, OT indicates outdoor termination.
Y indicates numbers of cores.
Heat Shrink Straight Joint
Cotran heat shrink straight through joints are precisely designed to meet the parameters of international cable and cable accessories standards such as CENELEC HD 629.1 S1, IEEE-48, IEEE-404, IEC60502. Our heat shrink straight through joints offers reliable and consistent performance for longer service life. We have designed our heat shrink straight through joint for single core and 3 cores extruded UA, SWA/STA, CWS/CTW cable through 36KV.
Main Kit Components
Insulation tube |
Stress control tube |
Semi-conductive/insulation tube |
Tube for outer jacket |
Metal shielding mesh |
Sealants |
Braid |
Silicone grease |
Spring roll |
Instruction |
|
|
Selective Chart
Part NO. |
Cable cross-section (mm2) |
O/D of main insulation (mm) |
Voltage |
CHSJ-SJ-15-Y/1 |
25~50 |
12.3~20.7 |
8.7/15kV |
CHSJ-SJ-15-Y/2 |
70~120 |
20.7~26.9 |
8.7/15kV |
CHSJ-SJ-15-Y/3 |
150~240 |
26.5~32.7 |
8.7/15kV |
CHSJ-SJ-15-Y/4 |
300~400 |
31.9~40.9 |
8.7/15kV |
CHSJ- SJ-24-Y/1 |
35~95 |
18.0~22.5 |
12/20kV |
CHSJ- SJ-24-Y/2 |
120~240 |
23.9~29.3 |
12/20kV |
CHSJ- SJ-24-Y/3 |
300~400 |
31.5~34.5 |
12/20kV |
CHSJ- SJ-36-Y/1 |
50~95 |
24.3~27.3 |
18/30kV |
CHSJ- SJ-36-Y/2 |
120~185 |
28.9~32 |
18/30kV |
CHSJ- SJ-36-Y/3 |
240~400 |
34.3~39.5 |
18/30kV |
Notes: Y indicates numbers of cores.