Cable Fireproof Coating KC2000

Sales Cable Fireproof Coating KC2000

◆ Completely meet the requirements of GB 28374-2012;

◆ Environmental protection halogen-free, non-toxic and harmless;

◆ Good flexibility;

◆ Good insulation performance;

◆ Strong adhesion;

◆ Good fire protection effect;

◆ Good anti-corrosion performance.

Product Detail  

Product Instruction

KC2000-E is a new type of fireproof coating for cable developed by our company according to GB 28374-2012 national standard. The product can produce uniform and dense spongy foam coating when subjected to fire, which can effectively inhibit and block the spread of flame. It can be used for fire protection of power cable body and joint, and also can be used for fire protection of cable thread at the bottom of switch cabinet. It has the advantages of environmental protection, no pollution, non-toxic and tasteless, strong adhesion and good flexibility.


Applications

  • Fire protection of cable body and joints
  • Fire protection for cable threading at the bottom of switchgear


Product Specification

Test Item

Typical Value

Test Standards

The state in the container

No caking, uniform state after stirring

visual

fineness

≤90μm

GB/T 6753.1

viscosity

≥70s

GB/T 1723

Table dry time

2~2.5h

GB/T 1728(Method A)

Full set time

About18h

GB/T 1728(Method A)

Oil resistance

No wrinkling, peeling or blistering after soaking for 7d

GB/T 28374-2012

Resistant to salt water

No wrinkling, peeling or blistering after soaking for 7d

GB/T 28374-2012

The wet and heat resistance

After 7d test, there was no cracking, peeling or blistering

GB/T 28374-2012

Resistance to freezing and thawing cycles

After 15 cycles, no wrinkling, peeling and blistering were observed

GB/T 28374-2012

Flex resistance

No layer, no peeling, no foaming

GB/T 28374-2012

Flame retardant

Carbonization height ≤2.50m

GB/T 28374-2012


Direction for Use

1. Before construction, clean the cable surface of dust, oil, impurities, etc. and carry out the construction of fireproof coating until the cable surface is dry;

2. When using, the fireproof coating should be fully stirred evenly;

3. Brush for 3 times, with an interval of 4h for each time and a thickness of 0.3~0.4mm for each time. The final coating can be formed after drying and the final coating thickness is about 1mm.

4. During the construction and before the coating is dry, it should be waterproof, anti-insolation, anti-pollution, anti-movement and anti-bending. If there is any damage, it should be repaired in time;

5. After the completion of construction, the coating should be uniform and smooth, with no obvious bump on the surface.


Package

25kg/barrel


Certificate


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.